Specifications
Ventilation modes
A/C-PC
Assist control (pressure control)
A/C-VC
Assist control (volume control)
CPAP
Continuous positive airway pressure
PSV
Pressure support ventilation
S/T
Spontaneous/timed ventilation
SIMV-PC
Synchronized intermittent mandatory ventilation (pressure control)
SIMV-VC
Synchronized intermittent mandatory ventilation (volume control)
MPV-PC
Mouthpiece ventilation (pressure control)
MPV-VC
Mouthpiece ventilation (volume control)
Physical
Weight
5.2 kg
Size
16.5 cm D x 28.6 cm W x 24.5 cm H 6.48” D x 11.25” W x 9.65” H
Screen dimensions
8”, 20.32 cm
Oxygen
Low flow
0 to 30 l/min; maximum 10 psi
High pressure
280 to 600 kPa (41 to 87 psi)
Measured and displayed patient parameters
Tidal volume (Vti or Vte)
0 to 2000 ml
Minute ventilation (MinVent)
0 to 30 l/min
Leak
0 to 200 l/min
Respiratory rate (RR)
0 to 90 BPM
Peak inspiratory flow (PIF)
0 to 200 l/min
Peak inspiratory pressure (PIP)
0 to 90 cmH2O
Mean airway pressure
0 to 90 cmH2O
Percentage spontaneous triggered breaths (%Spont Trig)
0 to 100%
I:E ratio
9.9:1 to 1:9.9
Dynamic compliance (Dyn C)
1 to 100 ml/cmH2O
Dynamic resistance (Dyn R)
5 to 200 cmH2O/l/sec
Dynamic plateau pressure (Dyn Pplat)
0 to 90 cmH2O
Auto-PEEP
0 to 20 cmH2O
FiO2 with FiO2 sensor
21% to 100%
SpO2 with pulse oximeter accessory
0 to 100%
Pulse rate with pulse oximeter accessory
18 to 321 beats per minute
EtCO2 with CO2 accessory
0 to 150 mmHg
Electrical
AC input voltage
100V - 240V, 50/60 Hz, 1.7 - 0.6A
DC input voltage
12/24V 6.5A
Internal and detachable Li-on batteries
15 hours’ nominal total run time per method in IEC 80601-2-72 (7.5 hours each battery)
Charge time for detachable and internal battery
from 0% to 80%: 2.5 hours; from 0% to 100%: 3.5 hours
Alarms
Inspiratory Pressure
PEEP+1 to 89 cmH2O
Tidal Volume
OFF, 10 - 2000 ml
Minute Ventilation
OFF, 0.2 - 30 L/min
Respiratory Rate
OFF, 1 - 90 BPM
Circuit Disconnection
OFF, 5 - 60 sec
Apnea Interval
5 to 60 sec
No trigger
OFF; 0.5-15 min (ONLY in MPV)
Controls
AVAPS with passive circuit
PSV, S/T, and A/C-PC modes only
Tidal volume
35 - 2000 ml on Dual Limb and Active Flow circuits, 50 - 2000 ml on passive and active PAP circuits
Breath rate
0 - 80 BPM
PEEP
0 - 35 cmH20 for active circuits 3 - 25 cmH20 for passive circuits
EPAP/CPAP
3 to 25 cmH20
IPAP
3 to 60 cmH20
Pressure support/pressure control
0 to 60 cmH20
Inspiratory time
0.3 - 5.0s
Rise time
0 to 6
Triggering and cycling
Off, AutoTrak, Sensitive, AutoTrak, and Flow Trigger
Flow trigger sensitivity
0.5 - 9 l/min
Flow cycle sensitivity
10% - 90% of peak flow
Flow pattern
Square, Ramp
FiO2
21% - 100%
Inspiratory time min/max
0.3 to 3.0 sec
Backup ventilation
ON-OFF